Can you have an MRI scan with an implant, a filling or braces?
Usually yes. Magnetic resonance imaging (MRI) produces images using a strong magnetic field and radiofrequency pulses, without ionising radiation. A literature review drawing on dental journals divides the adverse effects of dental materials in the MRI field into three groups: image distortion, known as artefacts, heating of the material and its displacement (Chockattu et al., 2018).
For most dental work, artefacts are the practical problem. A review of 18 studies considered heating and debonding of orthodontic brackets during the scan harmless to the patient, and whether fixed braces were compatible with MRI depended mainly on the extent of image distortion (Dobai et al., 2022). The exceptions are magnets in dentures and components made of strongly magnetic materials, which we describe below.
Before an MRI scan, you fill in a safety questionnaire. The UK’s NHS says that it asks, among other things, about metal in your body, and it gives fillings and bridges as examples. Tell the unit about all your dental work, including anything that seems unimportant, because the MRI staff decide how the scan is carried out.
Why does metal in the mouth distort a head MRI?
Artefacts form at the boundary between a material and tissues that respond differently to the magnetic field. These differences distort the image or cause signal loss, an empty, dark area in and around the metal. According to the review by Chockattu et al. (2018), distortion can also appear on a slice several layers away from the one containing the material, and the same material may make no difference to a brain MRI yet seriously distort images of the face and mouth.
The stainless steel in orthodontic brackets and archwires strongly distorts the magnetic field around it, so it causes large artefacts (Chockattu et al., 2018). In the review by Dobai et al. (2022), steel brackets and archwires distorted images of the facial region and could distort images of the frontal lobes, the eye sockets and the pituitary gland. Ceramic and plastic brackets did not cause significant artefacts.
Distortion does not always interfere with interpreting the scan, especially when it occurs outside the area the doctor wants to examine (Chockattu et al., 2018). In an MRI of the knee or the lumbar spine, dental work lies far from the area being scanned. It matters most in scans of the head, the neck, the temporomandibular joints and the teeth themselves.
Dental implants and MRI scans
Dental implants are made of titanium, a non-ferromagnetic material which nevertheless contains trace amounts of iron and can therefore cause signal loss right next to the implant surface. Study results vary: in one, titanium implants caused strong distortion in all planes, although less than orthodontic appliances, while in others the artefacts were small and did not interfere with interpreting the image (Chockattu et al., 2018).
In a study on a scanner designed for dental MRI, a titanium implant distorted the magnetic field more than a zirconia implant. In measurements on phantoms, the distortion increased with field strength, from 0.55 through 1.5 to 3 tesla. In a volunteer scanned at 0.55 tesla with implants held in a splint, titanium caused more artefacts than zirconia, visible mainly around the crowns of the teeth next to the implants (Johannsen et al., 2025).
The crown on the implant also matters. In a study at 3 tesla, a zirconia implant with a monolithic zirconia crown caused the fewest artefacts, and the least favourable combination was a titanium implant with a crown on a base metal alloy framework. Crowns made with a precious alloy or on zirconia caused less distortion than crowns containing cobalt, chromium and tungsten (Hilgenfeld et al., 2016).
The exception is magnetic denture attachments. The magnet sits in the denture, while a metal keeper stays in the mouth, screwed onto an implant or fixed to a tooth root. The review by Chockattu et al. (2018) states that keepers on implants cause large artefacts, so it is recommended that they are removed before a patient with implants is referred for an MRI scan. If you have a description of your implant type from your dentist, for example in your treatment records, take it with you to the scan.
Braces and a head MRI: do they need to be removed?
Fixed braces do not usually need to be removed for safety reasons. The review by Chockattu et al. (2018) states that well-bonded, carefully ligated fixed braces are safe in an MRI scanner, and that it is worth checking that a steel retainer is firmly bonded before the scan. In the review by Dobai et al. (2022), heating and debonding of components were harmless, but some archwires heated up more, so the authors suggest removing them or using a spacer to keep the brace away from the lining of the mouth.
The image is the problem. If the scan covers the area of the teeth and jaws, the review by Chockattu et al. (2018) recommends changing the scanning plane to avoid the metal and, where that is not possible, removing the brackets and archwires. Removing braces takes time, costs money and carries a risk of enamel damage, so the decision is made case by case. According to the authors of the review by Dobai et al. (2022), a wire retainer can be left in place when the scan does not cover the tissues of the mouth; in a scan of the mouth, a steel retainer can significantly distort the image.
- When you are referred for a head or neck MRI, tell the referring doctor and the MRI unit about your fixed braces.
- Call your orthodontist as early as possible: if the archwire has to come out, that appointment is booked before the scan date.
- Take out a removable appliance or a retention plate with metal wires before you enter the MRI unit, and ask the staff about aligners.
- After the scan, check with your tongue that the brackets and retainer are still firmly attached, and tell your orthodontist about any loose component.
Fillings, crowns, bridges and MRI scans: what do studies show?
Amalgam fillings have little effect on dental MRI images, because their main component, silver, is not ferromagnetic. In one laboratory study, teeth with amalgam fillings showed greater marginal leakage after MRI exposure, while another found no differences between types of amalgam (Chockattu et al., 2018). The review makes no recommendation to replace fillings before a scan.
Glass ionomer cements, gutta-percha and resin-based root canal sealer cause no detectable distortion. Composites from some manufacturers do not affect the image, while those from others cause noticeable distortion, depending on their pigments and fillers, such as ytterbium trifluoride or iron and lanthanum oxides. Data on fractured root canal instruments and silver points are lacking (Chockattu et al., 2018).
Crowns and bridges on a metal framework, whether made of precious alloys or of nickel-chromium or cobalt-chromium alloys, cause artefacts that increase with field strength. Results for zirconia are contradictory: in one study it caused barely visible distortion, while in another, in an MRI of the lower face, it distorted the image as much as metal. Suitably chosen scanning sequences can reduce distortion from porcelain-fused-to-metal crowns (Chockattu et al., 2018).
| Dental work | What studies say about safety | Distortion on head and neck images | What to do before the scan |
|---|---|---|---|
| Titanium implant | Titanium is not ferromagnetic | Small to strong, mainly around the implant and crown | Tell the MRI unit about the implant |
| Zirconia implant | Non-metallic material | Less than with titanium | Tell the MRI unit about the implant |
| Magnet keeper on an implant or root | Deflection forces exceeded permitted limits | Large | Discuss removing the keeper with your dentist before referral |
| Fixed braces with steel brackets | Heating and debonding harmless | Large in the facial area, also on brain images | Warn your orthodontist and the MRI unit, and consider removing the archwire together |
| Ceramic or plastic brackets | Safe in studies | No significant artefacts | Tell the MRI unit about your braces |
| Fixed wire retainer | Check it is firmly bonded before the scan | Significant in scans of the mouth | Tell the MRI unit, and for a scan of the mouth discuss it with your orthodontist |
| Amalgam filling | Greater marginal leakage in one laboratory study | Small | List your fillings on the questionnaire |
| Composite or glass ionomer filling, root canal treatment | No hazards described | None, or depending on the composite’s make-up | List your fillings on the questionnaire |
| Crown or bridge on metal | No hazards described | Clear, increasing with field strength | Tell the unit about your crowns and bridges |
| Zirconia crown or bridge | No hazards described | Contradictory study results | Tell the unit about your crowns and bridges |
Dentures, aligners and magnets: what should you take out before an MRI?
Magnetic denture attachments call for the most caution: the magnet in the denture and the metal keeper fixed to a tooth root or implant. In studies at 3 tesla, heating of these components posed no hazard, but the deflection forces in the magnetic field exceeded permitted limits. Ferromagnetic components are therefore best removed from the mouth before the scan and, where this is not possible, their attachment should be checked before and after the MRI (Chockattu et al., 2018).
A denture magnet can also lose strength. In a study using a 3 tesla scanner, the force of magnets placed in one of the orientations fell markedly after they were moved into and out of the scanner several times, so the authors recommend taking out every removable denture with magnets before an MRI scan (Hayashi et al., 2017). The keeper stays in your mouth when the denture is out, so tell the MRI unit about it separately.
The UK’s NHS asks you not to wear anything containing metal for the scan. So before you enter the MRI unit, take out a denture with a metal framework or clasps, a removable appliance or a retention plate with wires and put it in its case, and ask the staff about a denture without metal. Crowns, bridges, implants and fillings stay in place, because they cannot be removed without a procedure.
How does an MRI scan differ from a CBCT scan and a panoramic radiograph?
Magnetic resonance imaging and dental X-rays are different examinations. Panoramic radiographs, intraoral X-rays and CT scans use ionising radiation, whereas MRI does not. MRI shows both hard and soft tissues at high resolution, in different planes, and it is increasingly used in dentistry as well (Chockattu et al., 2018).
For dental diagnosis, the practice takes X-rays, and the dentist decides which examination is needed. In DentalBlue’s published price list, ‘Panoramic radiograph’ costs 120 zł, ‘CBCT scan, upper or lower jaw’ 300 zł and ‘CBCT scan, both jaws’ 350 zł. The clinic does not perform MRI scans.
MRI and teeth: a checklist before the scan and help at DentalBlue
Before you go for an MRI scan, especially of the head or neck, gather some information about your dental work. If you do not know what your crown is made of or which implant you have, ask the practice that provided it.
At DentalBlue in Białystok, dental images, from intraoral X-rays to CBCT scans, are taken in the clinic’s own radiology unit, and you can ask about work done at the clinic by calling 85 748 00 50. The clinic is at ul. Kazimierza Pułaskiego 35 in Białystok and is open Monday to Friday from 8:00 to 20:00 and Saturday from 8:00 to 16:00. The team speaks Polish, English, Ukrainian and Russian.
- A list of your dental work: implants, crowns, bridges, fillings, root canal treatment, fixed braces, a retainer, a denture and magnets.
- Details of the material of your crown or implant, if you have them in your records.
- With fixed braces: the scan date passed on to your orthodontist well in advance.
- A case for the denture, aligners or removable appliance that you will take out before the scan.
- After the scan: a check that your retainer, brackets and magnets are as firmly attached as before.
Frequently asked questions
Does a dental implant interfere with a head MRI?
An implant is not a contraindication, but it can distort the image in its vicinity. Titanium usually causes more distortion than zirconia, distortion increases with field strength, and the crown material plays a major role (Johannsen et al., 2025; Hilgenfeld et al., 2016). Tell the MRI unit about your implants before the scan.
Do braces have to be removed before an MRI?
Not usually for safety reasons. Steel brackets and archwires do, however, distort images of the face and brain, and when the scan covers the area of the teeth and the metal cannot be avoided, removing the brackets and archwires is recommended (Chockattu et al., 2018). Tell your orthodontist well in advance, because the decision is made before the scan date.
Are amalgam fillings a contraindication to an MRI?
No. Amalgam has little effect on the image, because its main component, silver, is not ferromagnetic. One laboratory study found greater marginal leakage of these fillings after MRI, but the review by Chockattu et al. (2018) makes no recommendation to replace fillings before a scan.
Can I have an MRI with a fixed retainer?
Usually yes. The authors of a review of 18 studies concluded that a wire retainer can be left in place when the scan does not cover the tissues of the mouth, because in a scan of the mouth a steel retainer can distort the image (Dobai et al., 2022). Before the scan, it is worth checking that the retainer is firmly bonded, and afterwards that nothing has come loose (Chockattu et al., 2018).
Do I have to take out my denture before an MRI?
A denture with magnets is always taken out, because the field can weaken the magnets (Hayashi et al., 2017), and the keeper that stays in your mouth is reported to the MRI unit. The NHS asks you not to wear anything containing metal for the scan, so take out a cast partial (framework) denture or a denture with metal clasps as well. Ask the MRI staff about a denture without metal.
Does metal in the mouth heat up during an MRI?
The heating described was slight: 3.04°C for some orthodontic archwires and 1.42°C for components of magnetic denture attachments at 3 tesla, against a pain threshold of 8 to 10°C for the lining of the mouth (Chockattu et al., 2018). For magnets and ferromagnetic components, checking their attachment before and after the scan is recommended.
Sources
- Chockattu SJ et al., Restor Dent Endod: dental materials and magnetic resonance imaging, literature review (2018)
- Dobai A et al., BMC Oral Health: orthodontic brackets and archwires and magnetic resonance imaging, systematic review (2022)
- Johannsen KM et al., Dentomaxillofac Radiol: titanium and zirconia implants and dental MRI images (2025)
- Hilgenfeld T et al., Eur J Oral Implantol: implant crown material and MRI artefacts (2016)
- Hayashi N et al., Radiol Phys Technol: denture magnets and 3 T MRI (2017)
- NHS: MRI scan, preparing for the scan (2025)
- DentalBlue: published price list (X-rays)
An informational article. It does not replace a consultation, and treatment decisions are made during a visit.